IEEE 802.3 Fibre Ethernet: SR, LR and DR Physical Layers

How IEEE 802.3 defines optical Ethernet PHYs from 1000BASE-SX to 400GBASE-SR4.2, with the fibre type and reach set for each.

IEEE 802.3 (optical PHYs) IEEE 802.3-2022 + amendments 4 min read

Base standard
802.3-2022
Active, with amendments
10GBASE-S
300 m
At 2000 MHz·km (OM3 grade)
40G/100G MMF
100 m
802.3ba objective on OM3
Full titleIEEE 802.3, IEEE Standard for Ethernet. Optical PHYs are specified in individual clauses, added by amendments
PublisherIEEE Standards Association, IEEE 802.3 Ethernet Working Group
Current editionIEEE 802.3-2022, published 29 July 2022. It supersedes IEEE 802.3-2018
StatusActive. Amended since 2022 by, among others, 802.3db-2022 and 802.3df-2024. A further revision project, P802.3, is authorised
Related standardsISO/IEC 11801-1, IEC 60793-2-10 (multimode fibre), ITU-T G.652, IEC 61280-4-1 and -4-2 (fibre testing), ANSI/TIA-568.3

What it covers

IEEE 802.3 defines Ethernet. Each optical physical layer (PHY) has its own clause, which sets the optical transmitter and receiver limits, the fibre type and the operating range. New PHYs are added by amendments, which are then folded into the next revision of the base standard.

This page lists the optical PHYs commonly used in buildings, campuses and data centres. Reach figures are taken from IEEE 802.3 tables or from the approved IEEE project objectives.

Reading the names

  • The number before BASE is the data rate, for example 10G or 400G.
  • S or SR PHYs run on multimode fibre (MMF) at short wavelengths, mostly around 850 nm. 400GBASE-SR4.2 uses two short wavelengths in both directions on each fibre.
  • A trailing number gives the parallel structure. 400GBASE-SR8 uses eight pairs of MMF. 400GBASE-SR4.2 uses four pairs.
  • LR, DR and FR PHYs run on single-mode fibre (SMF).

Multimode PHYs and reach

1000BASE-SX (Clause 38)

Operating range for 1000BASE-SX (IEEE 802.3 Clause 38):

FibreModal bandwidth at 850 nmRange
62.5 µm MMF160 MHz·km2 m to 220 m
62.5 µm MMF200 MHz·km2 m to 275 m
50 µm MMF400 MHz·km2 m to 500 m
50 µm MMF500 MHz·km2 m to 550 m
SMFN/ANot supported

10GBASE-SR (10GBASE-S, Clause 52)

FibreModal bandwidth at 850 nmOperating distance
62.5 µm MMF160 MHz·km26 m
62.5 µm MMF200 MHz·km33 m
50 µm MMF400 MHz·km66 m
50 µm MMF500 MHz·km82 m
50 µm MMF2000 MHz·km300 m

2000 MHz·km is the effective modal bandwidth of OM3 fibre. The table above shows the earlier fibre grades listed in Clause 52. See the current Clause 52 table for OM4.

25G to 400G multimode PHYs

AmendmentPHYsClauseIEEE reach objective
802.3ba-201040GBASE-SR4, 100GBASE-SR1086At least 100 m on OM3 MMF
802.3bm-2015100GBASE-SR495Up to at least 100 m of MMF
802.3by-201625GBASE-SR—Single lane, consistent with Clause 95
802.3cd-201850GBASE-SR, 100GBASE-SR2, 200GBASE-SR4138Up to at least 100 m of MMF
802.3bs-2017400GBASE-SR16—At least 100 m of MMF
802.3cm-2020400GBASE-SR8, 400GBASE-SR4.2138 (SR8) and 150 (SR4.2)At least 100 m on eight pairs (SR8) or four pairs (SR4.2) of MMF
802.3db-2022100GBASE-SR1/VR1, 200GBASE-SR2/VR2, 400GBASE-SR4/VR4167Up to at least 50 m and up to at least 100 m on one, two or four pairs of MMF

The reach objectives are minimum targets set when each project started. The published clauses give the operating range for each fibre grade, which can be shorter on OM3 than the headline objective. Check the clause table for the fibre installed.

Single-mode PHYs

AmendmentPHYs (examples)SMF reach objectives
802.3ae-200210GBASE-LR, 10GBASE-ERAt least 2 km, 10 km and 40 km over SMF
802.3ba-201040GBASE-LR4, 100GBASE-LR4, 100GBASE-ER440G: at least 10 km. 100G: at least 10 km and 40 km
802.3bs-2017400GBASE-DR4, 400GBASE-FR8, 400GBASE-LR8At least 500 m, 2 km and 10 km of SMF
802.3cd-2018100 Gb/s single-lane SMF PHYDuplex SMF, up to at least 500 m

The objectives list the reaches each project had to support. Which PHY meets which reach is set in the individual clauses and is not reproduced here.

How it relates to other standards

DocumentRelationship
IEC 60793-2-10 and ANSI/TIA-568.3Specify the multimode fibre categories and modal bandwidths that correspond to the OM3, OM4 and OM5 grades
ITU-T G.652Single-mode fibre characteristics
ISO/IEC 11801-1Defines optical fibre channel classes and lists supported applications
IEC 61280-4-1 and IEC 61280-4-2Field test methods for installed multimode and single-mode cabling
IEC 61754 seriesConnector interfaces such as LC and MPO used by duplex and parallel PHYs

What it means in practice

  • Reach depends on the fibre grade. Record the OM grade of installed multimode fibre before choosing optics.
  • Older 62.5 µm and 50 µm (400 to 500 MHz·km) fibre limits 10GBASE-SR to 82 m or less.
  • Parallel PHYs such as SR4, SR8 and DR4 need multi-fibre links, usually terminated with MPO connectors. Duplex PHYs need one fibre pair.
  • Each PHY also has a channel insertion loss limit. Test installed links and compare the loss with the limit for the intended PHY, not only the length.

Related reading: Single-mode vs multimode fibre: OM3, OM4 and OS2 · OM4 vs OM5 fibre.