+44 (0) 208 191 0156 Mon–Fri 9.30am–16:30pm
Alliance Member
B2B  ·  Manufacturer Direct Pricing Partner Application
0
0
Cabling Standards

ISO/IEC 11801-1: Generic Cabling for Customer Premises

The international base standard for generic cabling. Defines channel classes A to II, component categories and cabled fibre categories.

ISO/IEC 11801-1 2017+Amd 1:2025 4 min read

Edition
2017 + Amd 1:2025
Edition 1.1 consolidated
Balanced classes
A to II
Up to 2 000 MHz
New in Amd 1
T1-A, T1-B, T1-C
Single pair classes
Full titleInformation technology. Generic cabling for customer premises. Part 1: General requirements
PublisherISO and IEC, prepared by ISO/IEC JTC 1/SC 25
Current editionEdition 1, November 2017, with Corrigendum 1:2018 and Amendment 1:2025 (and its Corrigendum 1:2025)
StatusPublished and current
ReplacesWith ISO/IEC 11801-2, it cancels and replaces ISO/IEC 11801:2002 and its Amendments 1:2008 and 2:2010
Related standardsISO/IEC 11801-2 to -6, EN 50173-1, ANSI/TIA-568.2, ANSI/TIA-568.3

What it covers

ISO/IEC 11801-1 specifies the requirements that are common to the other parts of the ISO/IEC 11801 series. It describes a multi-vendor cabling system that supports voice, data, video and power delivery. It does not contain conformance requirements of its own. Those sit in the premises parts.

The scope covers:

  • structure and configuration of generic cabling
  • channel transmission, environmental and power delivery performance
  • link performance
  • backbone reference implementations
  • component requirements
  • test procedures

The ISO/IEC 11801 series

PartTitlePrevious document
11801-1General requirementsISO/IEC 11801
11801-2Office premisesISO/IEC 11801
11801-3Industrial premisesISO/IEC 24702
11801-4Single-tenant homesISO/IEC 15018
11801-5Data centresISO/IEC 24764
11801-6Distributed building servicesNew

The 2017 restructure brought the international series into line with the structure of the European EN 50173 series.

Changes in the 2017 edition

  • Re-structured to hold only the elements common to all generic cabling
  • Balanced cabling channel and link Classes BCT-B, I and II added
  • Coaxial cabling channel and link Class BCT-C added
  • Balanced component Categories BCT-B, 8.1 and 8.2 added
  • Cabled optical fibre Categories OS1a and OM5 added
  • Optical fibre classes (such as OF-300 and OF-500) removed
  • OM1, OM2 and OS1 moved to an informative annex

Amendment 1:2025

Amendment 1 (November 2025) adds single pair component Categories T1-A, T1-B and T1-C, and channel and link classes with the same names. Single pair cabling is intended for devices such as sensors, actuators and controllers in intelligent buildings and industrial automation. It does not replace 4-pair cabling.

The amendment also corrects the 2017 text, adds power delivery to the scope wording and adds references including ISO/IEC TS 29125 for remote powering and IEC 63171 for single pair connectors.

Classes and categories: ISO and TIA names

ISO uses classes for channels and links and categories for components. Some ISO category names differ from TIA names for similar performance.

ISO classSpecified up toISO component categoryNearest TIA category
Class D100 MHzCategory 5Category 5e
Class E250 MHzCategory 6Category 6
Class EA500 MHzCategory 6ACategory 6A
Class F600 MHzCategory 7Not recognised by TIA
Class FA1 000 MHzCategory 7ANot recognised by TIA
Class I2 000 MHzCategory 8.1Category 8
Class II2 000 MHzCategory 8.2No TIA equivalent

The standard also keeps the low-frequency Classes A (100 kHz), B (1 MHz) and C (16 MHz).

“Category 5e” is a TIA name. In ISO/IEC 11801-1 the components used for Class D are called Category 5.

Classes I and II

Classes I and II support 25GBASE-T and 40GBASE-T. The channel is limited to 30 m with no more than two connections. Category 8.1 components use the RJ45-style modular interface and are backward compatible with Class EA. Category 8.2 components use higher-performance shielded interfaces. Some, such as IEC 60603-7-82, are backward compatible with RJ45. Others, such as IEC 61076-3-104, are not.

BCT classes

Class BCT-B (balanced) and Class BCT-C (coaxial) support broadcast and communications technology (BCT) applications.

Cabled optical fibre categories

CategoryTypeEffective modal bandwidth at 850 nm
OM3Multimode 50/125 µm2 000 MHz·km
OM4Multimode 50/125 µm4 700 MHz·km
OM5Multimode 50/125 µm4 700 MHz·km, also specified at 953 nm
OS1aSingle-modeNot applicable
OS2Single-modeNot applicable

OS1a and OS2 are both specified at 1 310 nm, 1 383 nm and 1 550 nm. OS2 has the lower maximum attenuation and is the usual choice for longer runs.

How it relates to other standards

  • EN 50173-1:2018 is the European equivalent, with the same class and category names. In the UK it is published as BS EN 50173-1.
  • ANSI/TIA-568.2 covers twisted-pair components and cabling in North America. TIA Category 8 corresponds to ISO Class I with Category 8.1 components.
  • ANSI/TIA-568.3 covers optical fibre cabling and components and uses the same OM and OS names.

What it means in practice

  • When a specification calls for ISO/IEC 11801 compliance, check that components are rated to the ISO category, for example Category 6A to ISO/IEC 11801-1, not only to a TIA category.
  • Check that field test reports use ISO class limits (for example Class EA permanent link) where ISO is the contract standard.
  • Do not specify optical fibre classes such as OF-300. Specify the cabled fibre category and the application.
  • For short data centre links at 2 000 MHz, confirm whether Class I (RJ45-style) or Class II (Category 8.2 interfaces) is required.

Related reading: Cat5e vs Cat6 vs Cat6A: which cable is right? · OM4 vs OM5 fibre: what’s the difference?.

Share this article