IEC 60794 Series: Optical Fibre Cables

IEC series for optical fibre cables: generic spec and test methods in Part 1, sectional specs for indoor, outdoor, power line and microduct.

IEC 60794 series 60794-1-1:2023 4 min read

Generic specification
IEC 60794-1-1:2023
Edition 5.0
Sectional series
Parts 2 to 7
Indoor, outdoor, power line, microduct and more
No change, single-mode
≤ ±0.05 dB
Or ≤ ±0.05 dB/km
Full titleOptical fibre cables (all parts). Part 1-1: Generic specification. General
PublisherIEC, TC 86/SC 86A (Fibres and cables)
Current editionIEC 60794-1-1:2023 edition 5.0, published 22 May 2023. Other parts have their own editions, listed below
StatusPublished. The Part 1 test method documents are being split into single-method parts
Related standardsIEC 60793 series (optical fibres); ITU-T G.652 and G.657; ISO/IEC 11801-1; IEC 62807 series (hybrid cables)

What it covers

IEC 60794 is the IEC series for optical fibre cables used with communication equipment, including cables that also contain electrical conductors. The fibres themselves are specified in the IEC 60793 series. Hybrid communication cables are specified in the IEC 62807 series.

IEC 60794-1-1 sets uniform generic requirements for the geometrical, transmission, material, mechanical, ageing, climatic and electrical properties of cables and cable elements. Electrical properties are specified for optical ground wire (OPGW) and optical phase conductor (OPPC) cables. The 2023 edition was reorganised so that it acts as the reference document for the rest of the series, with tables naming every document in it.

How the series is built

Part titles use four levels of specification. Each lower level applies the requirements of the level above it.

  • Generic specification: IEC 60794-1-1, plus the test method parts of IEC 60794-1.
  • Sectional specifications: one per application area, such as IEC 60794-2 for indoor cables.
  • Family specifications: a cable family within a section, such as IEC 60794-2-10 for indoor simplex and duplex cables.
  • Detail specifications: requirements for a specific use, such as IEC 60794-2-11 for simplex and duplex cables in premises cabling.
Sectional partApplicationCurrent edition
IEC 60794-2Indoor cablesEd. 4.0, 2017
IEC 60794-3Outdoor cablesEd. 5.0, 2022
IEC 60794-4Aerial optical cables along electrical power linesEd. 2.0, 2018
IEC 60794-5Microduct cabling for installation by blowingEd. 2.0, 2014
IEC 60794-6Indoor-outdoor cablesSee family part 6-20

IEC 60794-1-1:2023 also lists an IEC 60794-7 series.

Sectional scopes

  • IEC 60794-2 gives the requirements for optical fibre cables for indoor use in communications networks.
  • IEC 60794-3 covers cables used externally: in ducts, directly buried, aerial, and lake and river crossings, plus specialised use in sewers and water and gas pipes. It excludes optical ground wires and cables attached to the phase or earth conductors of overhead power lines. The 2022 edition removed the ribbon specification, which is now in IEC 60794-1-31.
  • IEC 60794-4 covers aerial cables along power lines, including OPGW, OPPC, metallic aerial self-supported (MASS), all-dielectric self-supporting (ADSS) and optical attached (OPAC) cables. It excludes figure-8 cables on telephone poles.
  • IEC 60794-5 covers microduct optical fibre cables, microduct fibre units, microducts and protected microducts for installation by blowing, for outdoor and indoor use.

Family and detail specifications

PartContentCurrent edition
IEC 60794-2-10Indoor simplex and duplex cables, family specificationEd. 3.0, 2023
IEC 60794-2-11Simplex and duplex cables for premises cabling, detail specificationEd. 3.1, 2019 + A1:2020
IEC 60794-2-20Indoor multi-fibre cables, family specificationEd. 4.0, 2024
IEC 60794-2-21Multi-fibre distribution cables for premises cabling, detail specificationEd. 3.1, 2019 + A1:2020
IEC 60794-3-10Duct, directly buried and lashed aerial cablesEd. 3.0, 2015
IEC 60794-3-20Self-supporting aerial telecommunication cablesEd. 3.0, 2016
IEC 60794-4-10Optical ground wires (OPGW)Ed. 2.0, 2014
IEC 60794-4-20ADSS cables along power linesEd. 2.0, 2018
IEC 60794-5-10Outdoor microduct cables, microducts and protected microductsEd. 1.0, 2014
IEC 60794-5-20Outdoor microduct fibre units, microducts and protected microductsEd. 1.0, 2014
IEC 60794-6-20Flame retardant outdoor cables (indoor-outdoor)Ed. 1.0, 2020

IEC 60794-2-11 and -2-21 are written to ensure compatibility with ISO/IEC 11801 Parts 1 to 6. For cables in industrial premises, IEC 60794-2-10 and -2-20 note that MICE requirements from ISO/IEC 11801-1 may also apply.

Test methods

PartContentCurrent edition
IEC 60794-1-2Test procedures: general guidance and overview of all methodsEd. 5.0, 2021
IEC 60794-1-21Mechanical test methodsEd. 1.1, 2015 + A1:2020
IEC 60794-1-22Environmental test methodsEd. 2.0, 2017
IEC 60794-1-23Cable element test methodsEd. 2.0, 2019

IEC 60794-1-21 and IEC 60794-1-22 are being replaced one method at a time by single-method parts. This began in 2023 with IEC 60794-1-111. Mechanical methods move to IEC 60794-1-1xx parts and environmental methods to IEC 60794-1-2xx parts. Examples published in 2026 are IEC 60794-1-102 (abrasion, method E2), IEC 60794-1-131 (microduct inner clearance, method E31) and IEC 60794-1-210 (hydrostatic pressure, method F10).

Key definitions in IEC 60794-1-1

TermSingle-mode (class B)Multimode (category A1)
No change in attenuation≤ ±0.05 dB or ≤ ±0.05 dB/km≤ ±0.2 dB or ≤ ±0.2 dB/km
Maximum deviation, mechanical tests0.15 dB0.5 dB
Maximum deviation, environmental tests0.10 dB/km0.5 dB/km

Long-term load (TL) is the load a cable can carry in operation. For 1 % proof-tested fibre, fibre strain at TL must not exceed 20 % of proof strain (0.2 % absolute), with no change in attenuation. Short-term load (TS), often called rated installation load, must not cause fibre strain above 60 % of proof strain (0.6 % absolute).

What it means in practice

  • A cable datasheet should name the sectional, family or detail specification it meets, for example IEC 60794-2-21 for an indoor distribution cable.
  • Check that tensile ratings are stated as long-term and short-term loads, as defined in IEC 60794-1-1.
  • Check that test results quote the IEC 60794-1 method, such as E2 for abrasion.
  • Fibre performance comes from the IEC 60793 fibre specification. Fire performance for the installation is chosen separately, for example a CPR class to EN 50575.